59: If Flag/Port (P91)
1: 12 Do if Flag 2 is High
2: 30 Then Do
60: Set Port(s) (P20) ;
Port 1
(C1) is the heater control line
1: 0 C8..C5 = low/low/low/low
2: 1 C4..C1 = low/low/low/high
61: Beginning of Loop (P87)
1: 1 Delay
2: 0 Loop Count
62: Timer (P26)
1: 99 Loc [ _________ ]
63: If (X<=>F) (P89) ; Fire the heater for 1 s
1: 99 X Loc [ _________ ]
2: 3 >=
3: 1 F Change as required
4: 31 Exit Loop if True
64: End (P95)
65: Set Port(s) (P20)
1: 0 C8..C5 = low/low/low/low
2: 0 C4..C1 = low/low/low/low
66: Beginning of Loop (P87)
1: 1 Delay
2: 0 Loop Count
67: Timer (P26)
1: 99 Loc [ _________ ]
68: If (X<=>F) (P89) ; Wait 15 s for heat-pulse to arrive
1: 99 X Loc [ _________ ]
2: 3 >=
3: 15 F ; Change as required
4: 15 Set Flag 5 High
69: If Flag/Port (P91)
1: 15 Do if Flag 5 is High
2: 31 Exit Loop if True
70: End (P95)
71: Do (P86)
1: 22 Set Flag 2 Low
72: End (P95)
73: Batt Voltage (P10) ; Store battery voltage in Loc 98
1: 98 Loc [ _________ ]
Comments to this Manuals