9522B Iridium Satellite Modem and COM9522B Interface Modem
3.2.3 Step 3: DevConfig Communications
Once you have clicked Connect, you should be connected to the modem
(FIGURE 3-2).
FIGURE 3-2. Connected in DevConfig
Type the following command string that correlates to the datalogger and/or
Baud rate being used:
CR1000: AT&F0 S0=1 &D0 +IPR=6,0 V0 &K0 &W0 &Y0
CR10X: AT&F0 S0=1 &D0 +IPR=5,0 V0 &K0 &W0 &Y0
The appropriate command string will need to be used in both modems.
Press “Enter” once the string has been input. See FIGURE 3-3 and FIGURE
3-4 for an example.