Campbell CSIOPC User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 7
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
System Description
The CR10X consists of a Measurement and Control Module and a detachable Wiring Panel. The Mean Time Between
Failures (MTBF) for the CR10X is over 180 years. Standard operating range is -25° to +50°C; an optional extended
range of -55° to +85°C is available.
Measurement and Control Module
The module measures sensors, drives direct communications
and telecommunications, reduces data, controls external devices,
and stores data and programs in on-board, non-volatile storage.
The electronics are RF shielded and glitch protected by the
sealed, stainless steel canister. A battery-backed clock assures
accurate timekeeping. The module can simultaneously provide
measurement and communication functions.
The CR10X contains a comprehensive set of processing, math,
and program control instructions to build a datalogger program.
The maximum rate the CR10X can execute its program is 64
times per second. (The maximum rate a single input can be
measured is 750 samples per second.) Data and programs are
stored either in non-volatile Flash memory or battery-backed
SRAM. The standard memory stores 62,000 data points.
Optional versions store up to one million data points.
Datalogger Operating Systems
Options for the CR10X Operating System (OS) include array-
based, table, Pakbus, Modbus, and ALERT. The array-based OS
stores arrays of data at specified intervals or when a measured
condition has been met. Two final storage areas are provided
for storing the arrays. Table OS groups similar data in separate
tables. Pakbus OS enables the CR10X to communicate with
CR200-series dataloggers that are in the same network. Pakbus
OS stores data in the same format as the table OS. The Modbus
OS allows the CR10X to interface with SCADA or MMI software,
and ALERT OS allows the CR10X to be used in an ALERT sys-
tem. Operating System is specified at time of CR10X purchase
but can be changed easily if application needs change.
SC12 and SC12R-6 Cables
The SC12 is a two-foot cable that connects communication
devices to the CR10X’s 9-pin serial port. The SC12 is shipped
with most of our communication devices, including our phone
modems, satellite transmitters, and keyboard display. The
SC12R-6 is a six-foot cable that is purchased separately.
Wiring Panel
The Wiring Panel includes screw terminals for sensor connec-
tions and a 9-pin CS I/O port. An end bracket attaches the
Wiring Panel to the Control Module and to an enclosure-mount-
ed or free-standing baseplate. The Control Module easily dis-
connects from the Wiring Panel allowing field replacement with-
out rewiring the sensors. Gas tubes on the wiring panel provide
rugged electrostatic discharge protection.
SE
DIFF
G
GH L
12
1
AG H L AG H L AG E1 AG E2 G
34
2
56
3
SE
DIFF
G
GH L
78
4
AG H L AG H L AG E3 AG G G
910
5
11 12
6
P1 G P2 G C8 C7 C6 C5 C4 C3 C2 C1 G 12V 12V
SDM
5V 5V G G
SW 12V
SW 12V CTRL
Logan, Utah
G 12V
G 12V
POWER
IN
CR10X WIRING PANEL
MADE IN USA
WIRING
PANEL NO.
EARTH
GROUND
CS I/O
2 Pulse Counting Channels for
switch closures, high frequency
pulses, or low level ac
measurement.
1
2
3
A
4
5
6
B
7
8
9
C
*
0
#
D
C
R
1
0
K
D
K
E
Y
B
O
A
R
D
D
I
S
P
L
A
Y
S
E
R
I
A
L
i
/
O
M
A
D
E
I
N
U
S
A
C
R
1
0
X
M
E
A
S
U
R
E
M
E
N
T
A
N
D
C
O
N
T
R
O
L
M
O
D
U
L
E
f
i
r
m
w
a
r
e
1
9
8
3
,
1
9
8
6
,
1
9
9
5
S/N: X 1012
C
C
S
I
/
0
C
R
1
0
X
W
I
R
I
N
G
P
A
N
E
L
M
A
D
E
I
N
U
S
A
W
I
R
I
N
G
P
A
N
E
L
N
O
.
G
1
2
V
P
O
W
E
R
I
N
S
E
D
E
F
S
E
D
E
F
E
A
R
T
H
C
R
O
U
N
D
G
G
H
L
A
G
H
L
A
G
E
3
A
G
G
G
L
A
G
H
4
7
8
5
9
1
0
6
1
1
1
2
A
G
G
G
G
S
W
1
2
V
C
T
R
L
S
W
1
2
V
G
G
H
L
A
G
H
L
A
G
E
3
A
G
G
L
A
G
H
1
1
2
2
3
4
3
5
6
G
G
H
L
A
G
H
L
A
G
E
3
1
2
V
1
2
V
L
A
G
H
S
D
M
L
O
G
A
N
,
U
T
A
H
Aluminum Cover
(Included with CR10XTCR,
see page 6)
CR10XTCR
(optional see page 6)
Wiring Panel
End Bracket
SC12R-6 Cable
(not to scale)
CR10KD
(optional see
page 6)
Measurement
and Control
Module
Baseplate
5
6 Differential (12 single-ended)
Analog Inputs for measuring
voltage levels on five software
selectable voltage ranges.
3 Switched Excitation Channels
for precision excitation of sensors
or short-term actuation of exter-
nal devices. Excitation is pro-
grammable over a ±2500 mV
range.
Power and Ground Connections
for 12 V external batteries or per-
ipherals or for 5 V peripherals.
Switched 12 V terminal is controlled
by any digital output.
9-Pin CS I/O Port for connec-
tion of data storage, retrieval,
and telecommunications
peripherals.
8 Digital Inputs/Outputs for
output control, sensing status,
and reading SDM peripherals or
SDI-12 sensors.
Page view 3
1 2 3 4 5 6 7

Comments to this Manuals

No comments