CS100 Barometric
Pressure Sensor
Revision: 8/12
Copyright © 2002-2012
Campbell Scientific, Inc.
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Pressure Sensor

CS100 BarometricPressure SensorRevision: 8/12 Copyright © 2002-2012Campbell Scientific, Inc.

Page 2

CS100 Barometric Pressure Sensor 5. Choose the outputs for the barometric pressure and then select finish. 6. Remove the yellow warning label from

Page 3 - Warranty

CS100 Barometric Pressure Sensor isolated metallic surfaces. One of the surfaces is essentially a diaphragm constructed of a Setra’s proprietary comp

Page 4 - Assistance

CS100 Barometric Pressure Sensor 6. Specifications Features: • Integral switching circuit limits power consumption to measurement cycle • Compatib

Page 5 - Table of Contents

CS100 Barometric Pressure Sensor 6.1.2 Performance for “500 to 1100 mb” Range Option Measurement Range: 500 to 1100 mb Total Accuracy2: ±0.6 mb @ 2

Page 6 - Figures

CS100 Barometric Pressure Sensor 7. Installation 7.1 Enclosure Considerations To prevent condensation, install the sensor in an environmentally prot

Page 7 - 4. Quickstart

CS100 Barometric Pressure Sensor Remember that for the sensor to detect the external ambient pressure, the enclosure must vent to the atmosphere (i.e.

Page 8

CS100 Barometric Pressure Sensor TABLE 7-1. Signal and Ground Connectors for CS100 Wire CS100 Terminal Datalogger Single-Ended Measurement Datalog

Page 9

CS100 Barometric Pressure Sensor 7.3 Programming The CS100 sensor is measured using the singled-ended voltage measurement instruction (VoltSE() in CR

Page 10 - 5. Overview

CS100 Barometric Pressure Sensor 7.3.3 Program Examples The CS100 wiring instructions for the example programs are shown in TABLE 7-4 below. TABLE 7-

Page 11

CS100 Barometric Pressure Sensor EndIf 'Call Data Tables and Store Data CallTable(Table1) CallTable(Table2) NextScan EndProg 7.3.3.2

Page 13 - 6.3 Physical

CS100 Barometric Pressure Sensor 7.3.3.3 Edlog Example — CR10X Program Although this example is for a CR10X, other Edlog dataloggers, such as the CR5

Page 14 - 7. Installation

CS100 Barometric Pressure Sensor 9: Sample (P70) 1: 1 Reps 2: 1* Loc [ P_mb ] *Table 2 Program 02: 0.0000 Execution Interval (seco

Page 15 - 7.2 Wiring

CS100 Barometric Pressure Sensor The value dP is in millibars and the site elevation, E, is in meters. Add dP value to the offset in the measurement

Page 17 - 7.3 Programming

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 18 - 7.3.3 Program Examples

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Page 19

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Page 20

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Page 21 - 7.3.4 Output Resolution

Table of Contents ii Figures 5-1. CS100 Barometric Pressure Sensor... 5 7-1. ENC100 is a very smal

Page 22

CS100 Barometric Pressure Sensor 1. Introduction The CS100 measures barometric pressure for the range of 600 to 1100 mb. This range equates to from

Page 23

CS100 Barometric Pressure Sensor vertically downwards to prevent condensation collecting in the pressure cavity, and also to ensure that water cannot

Page 24

CS100 Barometric Pressure Sensor 3. Select CS100 Barometric Pressure Sensor then click the right arrow in the middle of the page to add the sensor to