Ap. Note – X-320
Environmental Sensor Compatibility
Rev: B
Date: 23 Feb 2011
Author: Eugene Bodrero
Last Update: 08 Feb 2012
Summary
The sensors listed in this document have been evaluated for compatibility with the X-320 inputs. The qualification
level of the sensors is assigned one of the following ranks.
P = Preliminary – Review of publicly available data indicates compatibility. Data may not include slope and
detailed electrical interface specifications.
D = Data sheet evaluation – Detailed review of electrical interface parameters. Slope and offset parameters are
given if indicated in data sheet information.
B = Bench tested – Evaluation units have been electrically connected to the X-320 and operated. Full slope,
offset, and any special electrical connections are given in the table or are available from Xytronix.
F = Field tested – Sensor has been connected to the X-320 and has been operated for an extended period of time
in a field environment.
Desired sensors may use the same output mode, such as 0-5 V analog output. Users are responsible for selecting the
appropriate sensors for their application and ensuring that the appropriate numbers of inputs or outputs are
available. The X-320 has four analog inputs, 2 counter inputs, and one frequency input.
Some environmental sensors combine multiple functions such as wind speed and wind direction. These sensors
typically have separate outputs for each function. Consequently, they are listed in multiple tables for each function
such as Wind Speed and Anemometer sections.
Xytronix Research and Design, Inc. Page 1
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1 - Ap. Note – X-320

Ap. Note – X-320 Environmental Sensor CompatibilityRev: BDate: 23 Feb 2011Author: Eugene BodreroLast Update: 08 Feb 2012SummaryThe sensors listed in t

Page 2 - Wind Speed (Anemometer)

X-320 Environmental Sensor CompatibilityOption 2 – Commercial/Research Weather StationFunction Manufacturer Model Price X-320 Connection Slope Offset

Page 3 - Temperature

X-320 Environmental Sensor CompatibilityRevision HistoryRev Description Author Approval Date Approved ByA Initial Release E. Bodrero 13. Apr. 2011 D.

Page 4 - Humidity

X-320 Environmental Sensor CompatibilityWind Speed (Anemometer)Make Model Output Power Mount ApproxPriceQual Slope Offset Connections NotesDavis 6410

Page 5 - Precipitation

X-320 Environmental Sensor CompatibilityWind DirectionMake Model Output Power Mount ApproxCostQual Slope Offset Connections NotesDavis 6410 n/a Vertic

Page 6 - Solar Radiation

X-320 Environmental Sensor CompatibilityMake Model Output Power Mount ApproxPriceQual Slope Offset Connections NotesYoung 41342VC 0-1 VDC 10-28 VDC Ra

Page 7 - Barometric Pressure

X-320 Environmental Sensor CompatibilityLightning DetectionMake Model Output Power Mount ApproxPriceQual Slope Offset Connections NotesWXLine StrikeGu

Page 8 - Water Level and Pressure

X-320 Environmental Sensor CompatibilitySolar RadiationSolar radiation configuration can be validated at clearskycalculator.com. The calculations assu

Page 9 - Station Configuration

X-320 Environmental Sensor CompatibilityBarometric PressureMake Model Output Power Mount ApproxPriceQual Slope Offset Connections NotesApogee Instrume

Page 10

X-320 Environmental Sensor CompatibilityWater Level and PressureMake Model Output Power Mount ApproxPriceQual Slope Offset Connections NotesSetra 528

Page 11 - Revision History

X-320 Environmental Sensor CompatibilityStation ConfigurationOption 1 – Low Cost Weather StationsFunctions Manufacturer Model Price X-320 Connection S