Installation, Operation and Maintainance of Automatic Meteorological Stations
Annex 7: Design of Met Station Compound
6.0m
B
B A A
Angle Iron to support corner post
A A
120
0
6.0m
120
0
120
0
Weather recorder
A A
Door frame angel iron
2”x2”x1/4”x8` Long
Door shutter
B A A
B
2.0m
0.5m
0.8m
0.5m
2.0m
A = Intermediate Post (line post)
B = Corner Post
Ground Plan of the Automatic Weather Station
Annexes